. Inverter Operation
Inverter OperationInverter Operation
Inverter Operation
N5000 INSTRUCTION MAN
N5000 INSTRUCTION MANN5000 INSTRUCTION MAN
N5000 INSTRUCTION MAN
UAL
UALUAL
UAL
4.3.10 Group A Screen 2
‘Group A Screen 2’ screen panel comes out when DOWN ( ) button in ‘Group A Screen 1’ screen
panel or UP ( ) button in ‘Group A Screen 3’ screen panel is touched. External signal source,
start/end frequency, start/end ratio, starting method, and external commanding filter are set
through this screen panel when external analog input/contacts are selected as a controller of
setting commanding frequency.
This screen panel also comes out when commanding frequency is set through external analog
input/contacts
Figure 17 Group A screen 2
When touching any button in the screen panel, 10KEY screen comes out for inputting values.
(1) External commanding channel: there are 4 external analog channels to set frequency and get
external signals. This button chooses one channel as a receiving terminal when output frequency is
set by external analog input.
(2) Start frequency: Set starting output frequency in [Hz] unit when the commanding frequency is
determined by the external analog input.
(3) End frequency: Set end output frequency in [Hz] unit when the commanding frequency is
determined by the external analog input.
(4) Start ratio: Set the ratio of starting output frequency when the commanding frequency is
determined by the external analog input.
(5) End ratio: Set the ratio of the end of output frequency when the commanding frequency is
determined by the external analog input.
(6) Starting method selection: selects starting method when the commanding frequency is
determined by the external analog input.
0: [Displays ‘Code’] generates ‘starting frequency’ output when output frequency is within
0 ~ start ratio.
1: [Displays ‘0Hz’] generates ‘0Hz’ output when output frequency is within 0~start ratio.