4.3.26 Group E Screen 3
‘Group E Screen 3’ screen panel comes out when DOWN button ( ) in ‘Group E Screen 2’ or UP
( ) button in ‘Group E Screen 4’ screen panel is touched. Initialization of fault and parameter
values is performed according to the set value, which is set in ‘Group B Screen 2’, when ‘START’
button is touched in this panel. And the progress is shown by the bar-graph and the text.
Figure 31 Group E screen 3
T
TT
Text on the screen
ext on the screenext on the screen
ext on the screen
Group B Screen 2
Group B Screen 2Group B Screen 2
Group B Screen 2
Description
DescriptionDescription
Description
NON 0 No initialization.
Trip 1 Initializes history of system failures and warnings.
Para 2 Initializes set values (parameters).
TIME 3 Initializes time.
All 4 Initializes all.
Initializ
InitializInitializ
Initializing
inging
ing
Initialize the error data and parameter
Initialize the error data and parameterInitialize the error data and parameter
Initialize the error data and parameter